HexaMole mascotHexaMoleInteractive Chemistry

Chemical ionization (CI)

Drag to turn the view. Scroll or pinch to zoom. Double-click to reset.

Inside the CI source

Chemical ionization is a soft method. Electrons ionize the reagent gas, which is present in huge excess. The reagent ions (CH₅⁺, H₃O⁺, t-C₄H₉⁺, NH₄⁺) then transfer a proton to the analyte: BH⁺ + M → MH⁺ + B. In the 3D view the source is filled with reagent gas at about 1 torr (pale dots, drawn far fewer than real); electrons enter through the wall and penetrate a few millimetres, losing their energy in collisions, so they ionize reagent mostly near the entrance (orange reagent ions), and after many collisions the reagent ions hand a proton to the analyte (pink MH⁺; violet fragments; blue ions made directly by electrons).

Reagent gas and proton affinity

The energy left in MH⁺ comes from the enthalpy of the proton transfer, ΔH = PA(B) − PA(M), where B is the neutral reagent (CH₄, H₂O, isobutene, NH₃). The more negative ΔH, the more energy MH⁺ keeps and the more it fragments: methane (PA 543.5 kJ/mol) is the hardest proton donor, then water (691.0), isobutane (802.1) and ammonia (853.6), which is the gentlest and gives mostly [M+H]⁺. The lower chart compares the degree of fragmentation for all five gases with the same analyte. If PA(M) is below PA(B), proton transfer is uphill (ΔH > 0); with ammonia you then see the [M+NH₄]⁺ adduct instead. Helium works differently, by charge exchange (He⁺• + M → M⁺• + He): it has no proton to give, and the energy released, RE − IE (24.6 eV minus the analyte’s ionization energy), is so large that the molecule shatters even more than in EI.

Pressure and collisions

The mean free path λ = kBT/(√2·π·d²·P) is the average distance a molecule travels between collisions. At CI pressures (about 1 torr) λ is tens of micrometers and every ion collides hundreds of times, which is what lets reagent ions react with the analyte. Lower the pressure in CI mode and watch collisions, and CI, disappear.

CI versus EI

The same analyte by EI and by CI: EI gives the fragment fingerprint, CI keeps the molecular mass visible as [M+H]⁺ (or [M+NH₄]⁺ with ammonia).

CI challenge

Find the main ion, choose the gentlest reagent, compute the energy left in MH⁺, and predict what ammonia gives when proton transfer is uphill.

Settings used

Proton affinities and ionization energies are literature (NIST) values. EI spectra are simplified versions of the main library peaks. The fragmentation of MH⁺, the fraction of ions formed by CI at a given pressure, and the adduct intensities are simple models chosen to show the trends. The animation is not to scale. All of this is carried over unchanged from the Ionization Explorer; lecture-specific content will be added when the lecture notes arrive.