A zinc strip in zinc sulfate and a copper strip in copper sulfate, joined by a wire and a salt bridge (the Daniell cell). Zinc atoms give up electrons and leave as Zn²⁺; the electrons travel through the wire, never through the solution, to the copper, where Cu²⁺ ions take them and become copper metal. Inside the solutions and the bridge, the charge is carried by ions: NO₃⁻ comes out of the bridge into the zinc beaker and K⁺ into the copper beaker, so both beakers stay electrically neutral at every moment (the Diagram counts the charges). With a voltmeter alone almost no current flows and nothing changes. With the bulb, the cell runs: the zinc gets thinner, the copper thicker, the blue colour fades, and the voltage stays near 1.10 V for a long time, then falls quickly as the last Cu²⁺ is used up. At the end E = 0.000 V because the reaction has reached equilibrium (Q = K). Assumed: 100 mL of each solution at 1.00 M, a 10 Ω bulb and 2 Ω of internal resistance; in this simple picture the bridge ions carry all the charge across the junctions (in a real cell some metal ions drift into the bridge too). Each sphere stands for 0.005 mol of ions, and the time is compressed: the full run takes about 59 hours.
Zoom in on a slice about 1.5 nm across of each electrode surface, with atoms, ions and water molecules at their real sizes. At the zinc, an atom at the edge of a surface step gives its two electrons to the sea of free electrons in the metal (they leave through the wire), shrinks from a 134 pm atom to a 74 pm Zn²⁺ ion, gathers six water molecules with their oxygen ends pointing at it, and drifts away as [Zn(H₂O)₆]²⁺. At the copper, a hydrated Cu²⁺ ion arrives, sheds its water, and takes its electrons one at a time: first Cu²⁺ + e⁻ → Cu⁺ (the slow step), then Cu⁺ + e⁻ → Cu (fast), as measured by Mattsson and Bockris (1959). The new copper atom joins the step. The counters show that every zinc atom oxidized matches one copper ion reduced. On screen one event takes 2.5 s; in the cell, at 92 mA, about 2.9 × 10¹⁷ happen every second. The Diagram shows why the electrons move: electrons in zinc sit 1.104 eV higher in energy than in copper, so they fall through the wire, delivering that energy to the bulb (minus what the 2 Ω internal resistance turns into heat). With a voltmeter only, nothing flows overall, but the surfaces are not frozen: atoms leave and ions return at equal rates (dynamic equilibrium). Schematic: the exact positions of water at the surface and the path an ion takes are drawn, not computed.
The Diagram draws the Nernst equation itself, term by term: the E° bar is set by the two metals, the correction bar −(RT/nF) ln Q shifts it (red when it lowers E, green when it raises it), and the result is E. Below, a log Q scale shows where the cell is now and where it is heading: it runs until Q reaches K, where E = 0. The cell voltage depends on concentration through the Nernst equation, E = E° − (2.303RT/nF) log Q. For the Zn | Cu cell n = 2, so E changes by 29.58 mV for each tenfold change in [Zn²⁺]/[Cu²⁺] at 25 °C; the slope grows with temperature (E° is held at its 25 °C value). The Diagram shows each electrode's own potential against the standard hydrogen electrode; the cell voltage is the gap between them. In a concentration cell both electrodes are copper, so E° = 0, yet a voltage appears when the concentrations differ. Press play and the dilute side dissolves copper while the concentrated side plates it out, until both are equal and E = 0.000 V.
Pick any two half-cells at 1 M. The one with the lower standard reduction potential is oxidized (the anode, marked −); electrons flow through the wire to the other (the cathode, +). E°cell = E°cathode − E°anode, and the reduction potentials are never multiplied by the coefficients. ΔG° = −nFE° and K = 10^(nE°/0.05916 V) follow from it. A single electrode potential cannot be measured: it is always read against a reference. Switch between the standard hydrogen electrode, the saturated calomel electrode (+0.241 V vs SHE) and Ag/AgCl in saturated KCl (+0.197 V): every electrode reading shifts by the same amount and the cell voltage stays the same. Standard potentials are from the CRC Handbook electrochemical series. Magnesium and aluminium are covered by oxide films in real cells, so measured voltages with them are lower than these values.
Two real batteries, cut open. In an alkaline AA cell (a primary battery), zinc gel in the centre is the anode: Zn + 2OH⁻ → ZnO + H₂O + 2e⁻. The electrons travel through the zinc gel to the brass nail, out of the − terminal, through the bulb, back in at the + terminal and down the steel can into the MnO₂/graphite cathode: 2MnO₂ + H₂O + 2e⁻ → Mn₂O₃ + 2OH⁻ (E°cell = 1.43 V; like the zinc–carbon dry cell it replaced, it is rated at about 1.5 V). No electron ever crosses the separator: inside, OH⁻ ions carry the charge, and the OH⁻ made at the cathode is used at the anode. Pushed backwards, an alkaline cell does not rebuild its zinc and MnO₂ reliably, and attempts to recharge it often make it rupture and leak KOH (OpenStax), which is why it is made to be used once; the bubbles drawn when you try are schematic. In a lithium-ion cell (a secondary, rechargeable battery), Li⁺ ions sit between the layers of graphite. When the cell is used, each Li⁺ crosses the separator and slips between the CoO₂ layers of the cathode while one electron goes round the wire (about 3.7 V). Nothing is used up: charging pushes the electrons and the Li⁺ back into the graphite. The Diagram counts electrons through the wire against ionic charge through the separator: always equal. Capacities per gram come from Faraday's law (26.80 Ah per mole of electrons): zinc 819.9 mAh/g, MnO₂ 308.3, graphite as LiC₆ 371.9, LiCoO₂ 273.8 (only about half of the lithium is used, 136.9). Choose the Daniell cell to recharge it with a power supply: the current is (V − E)/R with an assumed 2 Ω internal resistance and no overpotential, and the zinc plated follows Faraday's law. Reactions and voltages: OpenStax Chemistry 2e, section 17.5. The grains, ions and electrons are tokens: each stands for a huge number, and the layers are not to scale.
An electrolytic cell uses electrical energy to drive a reaction that would not run by itself. Gold-plating a ring: the ring is the cathode in a potassium dicyanoaurate bath, K[Au(CN)₂]; each [Au(CN)₂]⁻ ion that reaches the ring takes one electron and leaves a gold atom behind ([Au(CN)₂]⁻ + e⁻ → Au + 2CN⁻, E° = −0.611 V), while oxygen forms at an inert platinized-titanium anode. Switch to the atom view to watch it happen on the silver surface; gold atoms are almost exactly the size of silver atoms, so they continue the silver lattice. Faraday's law turns current and time into mass and thickness (100% current efficiency and a 6.0 cm² ring assumed); real gold plate is a few hundred nanometres to a few micrometres thick. Which ion reacts: in water several species compete at each electrode. At the cathode the easiest reduction wins (the highest E°, if enough of that species is present), at the anode the easiest oxidation (the lowest E°), unless that reaction is slow. In salt water, water is reduced to H₂ rather than Na⁺ to sodium, and chlorine forms at the anode even though oxygen should be easier, because oxygen has a high overpotential (OpenStax §17.7). The minimum voltages come from standard potentials; real cells need more because of overpotential and resistance.
Five kinds of question rotate: E°cell from a table, who carries the charge, the Nernst equation, Faraday's law, and K from E°. Every number you need is in the Conditions box. A wrong answer is crossed out and you can try again; ★ counts questions right on the first try. Hint gives the method; Show the solution asks twice whether you are sure before showing the worked solution.
Standard potentials: CRC Handbook of Chemistry and Physics, Electrochemical Series. Reference electrodes: Harris, Quantitative Chemical Analysis; Analytical Sciences Digital Library. Worked Faraday examples: OpenStax Chemistry 2e, section 17.7. Common misconceptions addressed: Sanger and Greenbowe, J. Res. Sci. Teach. 34, 377 (1997).